Will your machine work the same with a new temperature controller?

Table of Contents
    Add a header to begin generating the table of contents
    CONTROLLERS · REPLACEMENT

    What to check before you approve a replacement controller

    When a controller needs replacing, you want the machine working again without another problem. A unit that fits the panel and shows the temperature looks like a good start. You still need to know how it will control the equipment.

    PDF
    Download this checklist as a PDFThree checks before you choose a replacement controller.
    Download PDF
    Equipment panel 4.0 DISPLAY WORKS Fits Probe Which signal? Load Which rating? Same function? Not checked yet
    Fitting the panel is not the same as doing the same job. Illustration only.

    Will it switch the heater or compressor at the right moment?

    What will it do if a temperature sensor fails?

    At Chillventa Congress 2026, IEA HPT Project 65 organised a workshop on keeping heat pump components in use for longer.[5][6] A controller replacement brings that topic to a practical decision: what needs to match so the machine keeps working as intended?

    Three checks before you choose

    ASHRAE describes the sensor, controller and controlled device as parts of the same control system.[7] When you change the controller, check how it works with the parts that remain.

    Sensor Input Controller Behaviour Controlled device Outputs Process Temperature in the cabinet, room or cold store

    Tick each check when it is done.

    0 of 3 checked

    A heating cabinet shows why this matters

    Heater Probe 65 Controller ✓ Reads the probe ✓ Switches the heater ? Stops at the right temperature ? Reacts if the probe fails
    Explanatory example. It is not a KELD case study.

    The new controller may read the temperature sensor, or probe, and switch the heater correctly. You still need to check that heating stops at the right temperature and that the machine reacts correctly if the probe fails.

    Compare the settings with the approved record for that machine version. Do not rely only on settings copied from the faulty unit. Keep the confirmed settings with the wiring diagram.

    VIDEO

    Meet the KTS Series

    Meet Jorge Lacasa, our R&D and Quality Engineer. In this short video, he presents our KTS temperature controllers.

    KELD

    How KELD can help

    Send us your wiring diagram, sensor details and approved settings. In a 30-minute technical review, we check which KTS model suits your machine and what settings it needs.[8]

    1 Wiring diagram2 Sensor details3 Approved settings

    With KTS, you can check or set parameters from a phone using NFC, even before the controller has power. We can also define the default settings with your team, so the units arrive configured for your machine.[8]

    If your application needs more than a standard model, we can review a firmware change or a custom controller with you.[8]

    Book a 30-minute technical review →

    PDF
    Keep this checklist for your next replacementDownload the PDF version.